Determination of Hot Water Extract
Submitted on behalf of the EBC Analysis Committee
Keywords:
Collaborative trial, hot water extract (determination of), extract difference (determination of), malt (analysis method for)Abstract
The Analysis Committee of the European Brewery Convention has recommended that the Hot Water Extrat procedure for malt, which relies on a coarse grind and single temperature mash (65°C), is included in Analytica-EBC, as an additional method to that of the EBC Extract procedure. The Committee accepted the precision values obtained by the Institute of Brewing on the 1984 Check Malt. Repeatability (r₉₅) and reproducibility (R₉₅) values in litre degrees/kg were 2.14 and 3.48 respectively, for a mean value of 295.3 at Miag 0.7 mm setting, and 1.93 and 2.90 respectively, for a mean value of 298.2 at a Miag 0.2 mm setting.