Airborne microorganisms in the brewery filling area and their effect on microbiological stability of beer

Authors

  • Erna Henriksson
  • Auli Haikara

Keywords:

Microbiological analysis result, detection of microbial contaminants (method of)

Abstract

The levels of bacteria, moulds and yeast in the air of the filling area were examined in ten breweries and one soft drink factory. The total bacterial count was on average 4000 CFU/m³ in the air of the filling lines and the amount of anaerobically growing potential beer -spiling bacteria was 260 CFU/m³. The anaerobically growing bacteria consisted mainly of lactic acid bacteria. In addition strictly anaerobic Pectinatus cerevisiiphilus was isolated from the air in two breweries. The counts of anaerobically growing bacteria in the air of the beer bottling lines were three times higher in those breweries experiencing microbiological problems in bottled beer at the time of sampling than in other breweries. High temperature and relative humidity explained a significant part of the high microbial counts. The construction and location of the machinery in the filling hall also influenced the microbial counts.

Published

1991-01-31

How to Cite